Quid est Flow Meter Magnetic?

Flow Magnetic Meter est fluxus metricus qui fluxum humorum conductivorum mensurat. Abbreviated ut EMF, etiam fluvii Electromagnetici dicuntur. Est metri genus Volumetric profluvium. Magnetica metri fluxus velocitatem liquorum conductivorum per fistulam vel ductum moventium mensurat. In wastewater curationis industriae, Fluxus Magneticus Meter est optimus metri optio fluxus.

  • Mensurae liquidae vel slurriae liquidae quae minimum conductivity 5 µS/cm habent.
  • Genus sanitarium, PTFE materiae anticorrosivae libitum sunt.
  • Fibulae, flanges, insertio institutionis ad libitum sunt.
  • Pugna ad libitum powered.
  • Sumptus parvus.
  • DN 6 ad DN2000
  • Magna cura: 0.5%, 0.2% optional

Sino-Inst varias metrorum fluxus Magnetici praebet mensurae profluentiae. Si quaestiones habes, colloquere fabrum venditiones nostras.

Featured Magnetic flow Meters

Flow metres Features Magnetic

  • Mensuratio non afficitur varietate densitatis fluxus, viscositas, temperatura, pressio et conductivity. Mensuratio alta accurate praestatur secundum principium mensurae linearis.
  • Nullum impedimentum in tibia, nullum pressionis damnum et requisitio inferioris pipelinei rectae.
    DN 6 ad DN2000 amplis magnitudinis fistulae tegit. Varietas liners et electrodes in promptu sunt ad satisfaciendum diversae notae fluxus.
  • Programmable humilis frequentia campi excitatio undam quadratam. Mensuratio melioris stabilitatis et potestatis consummatio minuens.
  • 16 bits MCU deducentes, altam integrationem et accurationem praestant.
  • Processus digitalis plenus, strepitus altus resistentiae et mensurae certae. Influunt mensurae mensurae usque ad 1500:1.
  • High definition LCD propono cum backlight.
  • RS485 vel RS232 interfaciei subsidia digitalis communicationis. Intelligent fistulam vacuam detectionem et electrodes resistentiae mensurae diagnoses fistulam inanem et contaminationem electrodes accurate.
  • SMD componentes et superficies technologiae mons (SMT) ad effectum adduci meliores sunt.

Magnetica fluxus metri operationis principium

Magnetica metra fluxus metrorum utuntur principio Inductionis Faraday Legis Electromagneticae ad metiendam rate fluxum liquidi in tibia. In partibus fistulae fluens magnetici, campus magneticus generatur, et in liquidum per fistulam fluens canaliculatur. 

Lex Faraday asserit intentionem generatam esse proportionem motui liquidi fluentis. conductor per campum magneticum movens signum electricum intra conductorem producit. Singalum autem est proportionale velocitati aquae per campum moto. 

Sicut fluidum per campum magneticum fluit, particulae conductivae in fluido mutationes creant. Haec variatio ad mensurandum et calculandum velocitatem aquae per fistulam defluentis adhibetur. Ubi fluidum velocius movetur, magis generatur intentione. Transfusor electronic processit signum voltagenum ad liquidum fluxum determinare.

Magnetica fluxus metri principium – Formulae Faraday

Faraday's Formulae
E proportionalis est ipsi V x B x D ubi;

E = Voltage in conductore generatae
V = Velocitas conductoris
B = De propinquo vi
D = Longitudo conductoris

Quid est principium metri magneticae fluxus?

Ad hoc principium applicare mensurationem fluere cum metro magnetico. Primum est dicere liquorem metiendum esse electrically conductivum ad principium Faraday applicandum.

Secundum consilium fluxus magneticae metrorum applicata, Lex Faraday indicat: signum intentionis (E) dependens ab V, B, DV velocitas liquida mediocris est;

B robur campi magnetici est ;

D longitudo conductoris est (quae hic est distantia inter electrodes).

Ut plura de Metris fluere Magneticis discamus, hoc video per Emerson bene explicandum.
Vide fontem: https://www.youtube.com/watch?reload=9&v=lRSjYjg9WRo

Commoda utendi Electromagnetica fluunt Metra.

  • Magna cura et stabilitas
  • Reprehendo se,
  • Duo-modo measurement
  • Nulla pressura damnum
  • Non movens partes
  • Sit enim sanitate proposita
  • Magnitudinem praesto
  • Sordida liquida et mixta fructose sunt ok

Magnetic flow incommoda utendi metris

  • Mensurari gas, vaporis et liquores multum gasi continere non possunt;
  • Instrumentis liquidis metiri non potest cum conductivity nimis humilis.
  • Non possunt media caliditas metiri. Nunc restringitur per tunicam materialem et insulationem electricam materiam mensurae tubi electromagnetici fluxi metiendi pro industria generali;
  • Flos electromagneticus facile afficitur ab impedimento electromagnetico externo.

Magnetica fluxus metri diagram

Dimensiones Converter, ut Fig.

Magnetica fluxus metri diagram

Dimensiones Sensor, ut Fig.

Magnetica metri schematis profluvium sensorem

Attende:

1. Nominal Pressure 4.0 MPa pro DN10-150; Pressura nominalis 1.6 MPa pro DN10-1000; Nominal Pressure 1.0 MPa pro DN10-1600; Nominalis Pressurae 0.6 MPa pro DN10-2000. Alia pressio specialis gradus in demanda designari potest.

2. Longitudo L 6 mm crescit si humus LABIUM ornatur; Longitudo L 6 mm crescit si limbus praesidio LABIUM instructum est; Longitudo L 6 mm crescit si liner munimentum LABIUM instructum est.

Fluxus magneticus meter accurate

Accurate fluens electromagnetici supplevit Sino-Inst 0.5%, 0.2% ad libitum.

Quomodo intelligatur subtiliter fluens electromagneticus?

Valor absolutus differentiae inter valorem mensuratum et verum valorem comparatur cum vero valore, et numerus ante recipis consecuti accurate est. Si numerus minor est quam 0.5 et maior quam 0.2, accuratio generalis gradus 0.5 appellatur.

Exempli gratia: valorem mensuratum 100.5 vel 99.5, verum valorem 100 est, et recipis partem consecutus est 0.5%, quod significat accurationem 0.5. Si autem numerus ante recipis partem minor est quam vel aequalis 0.2, id accurate 0.2 dicitur.

Ut:

  • Rosemount magneticus fluit metri accuratio: Usque ad 0.15% fluxus volutricis rate accurate super 13:1 fluunt turndowns, 0.25% super 40:1 fluunt turndown
  • Yokogawa fluxus magneticus metri accuratio: ±0.35% profluentiae rate

Plura de lege: Cur Turndown Ratio Maximus?

Magnetic Flometer Applications

Flumina electromagnetica plus quam 50 annos adhibita sunt et late orbem terrarum usi sunt. Agri involvunt aquam/ purgationem, chemica, medicamenta, chartam, cibum et alias industrias.

Metra magna-genia plerumque in aquarum copia et inficio incepta adhibentur.

Caliberi parvi et medii saepe adhibentur in locis ubi solidi et liquidi sunt et pares et difficiles ad deprehendendas liquores vel ad alta requisita.

Caliberi parvi et parvi caliberi saepe in locis cum hygiene requisitis adhibentur sicut industria pharmaceutica, industria cibi, et machinatio biologica.

  • Aqua / Wastewater Industry
  • Cibum et potum
  • Metallum
  • Destillatio, distillatio, et vinum fabricatio
  • HVAC
  • Chemical
  • Chartam et pulpam
  • Pharmaceutical
  • Mining, Mineral Processing

Lectio extensa: Metallum Tube Flow Meter Applications

Metrum magneticum fluxus fermentum

Omnis mensurae processus singularis est. Quodlibet instrumentum potest habere problemata in usu.

In processu programmatis electromagnetici, si quaestio mensurae est. Quaeso reprehendo utrum problemata sequentia prius occurrant, et solutiones respondentes experire.

Si quaestio infra non recensetur, pete virgam in tempore Sino-Inst. Tibi suggestiones pro problematis solvendis dabimus.

phaenomenonSolutio
quod nullaa) Perscriptio nexus copiae potestatis;
b) Orthographiam fuse;
c) Compesce copiam intentionum potestatis;
d) Perscriptio si LCD antithesin componi potest. Aptet si fieri potest;
e) Redi ad turpia, si a) ad d) OK.
Coil Alarma) Perscriptio si terminalis EXT+ et EXT- aperta sunt;
b) Reprehendo si resistentia coil minus quam 150Q est;
c) Repone converti si a) et b) OK sunt.
Vana Pipe Terror et Electrodes Alarma) Orthographiam si fistula sensoria humore impletur;
b) Perscriptio nexus signo wiring;
c) Coniunge terminalem SIG1, SIG2 et SIG GND. Si terror ostentationis evanescit, convertentis confirmatum est normale. Trepidatio causari potest per bulliam in fluido;
d) Ad terrorem electrodes, resistentiam inter duos electrodes cum multimetro metire. Legendum esse debet inter 3 ad 50k. Alioquin contaminantur electrodes vel obteguntur.
princeps Turbato per metumProfluvium amplio auge.
humilis Turbato per metumDiminuere, fluere, complecti.
Parum mensuraea) Perscriptio si fistula sensoria liquore metienda impleatur.
b) Perscriptio wiring;
c) Perscriptio si factor sensoris et nulla fluunt, eaedem sunt ac quae in calibratiis scheda.

Lectio extensa: Guida: Magnetic Flometer Installation

Magneticum metrum pretium fluxus

Fluxus Magneticus Meter varias calibres, varias materias, alia media, diversa liniamenta, diversa capita metrica, et munera diversa, pretium diversum est!

Fluxus Magneticus Meter pretium album adnectitur infra pro tantum referente!

Ultima sententia parametri subiacet!

Diameter/DNFlexilis oblinit (USD)Derecta PTFE (USD)Electrodepotestatem Material
DN15485 647 316L (Latin configuration)24V / 220VChalybe
DN20493 647 316L (Latin configuration)24V / 220VChalybe
DN25500 647 316L (Latin configuration)24V / 220VChalybe
DN32537 654 316L (Latin configuration)24V / 220VChalybe
DN40566 654 316L (Latin configuration)24V / 220VChalybe
DN50588 662 316L (Latin configuration)24V / 220VChalybe
DN65618 676 316L (Latin configuration)24V / 220VChalybe
DN80676 691 316L (Latin configuration)24V / 220VChalybe
DN100706 750 316L (Latin configuration)24V / 220VChalybe
DN150728 794 316L (Latin configuration)24V / 220VChalybe
DN200757 838 316L (Latin configuration)24V / 220VChalybe
DN250809 985 316L (Latin configuration)24V / 220VChalybe
DN300926 1118 316L (Latin configuration)24V / 220VChalybe
DN350985 1368 316L (Latin configuration)24V / 220VChalybe
DN4001081 1441 316L (Latin configuration)24V / 220VChalybe
DN5001184 1765 316L (Latin configuration)24V / 220VChalybe
DN6001368 1904 316L (Latin configuration)24V / 220VChalybe
DN7001640 3574 316L (Latin configuration)24V / 220VChalybe
DN8002556 3868 316L (Latin configuration)24V / 220VChalybe
DN9003088 4574 316L (Latin configuration)24V / 220VChalybe
DN10004044 5926 316L (Latin configuration)24V / 220VChalybe
Nota: fluxores electromagnetici diversi sunt in pretio propter diversas caliberas, materias diversas, media diversa, et functiones diversae!

Pretium factores afficientes metris magnetici

  1. Maior diam cursus, pretium. Pro exemplo, DN250 fluxus electromagneticus carior est quam DN25 fluxus electromagneticus. Immo dia minora, minore pretio.
  2. Flometer dividitur in: genus integratum et genus scissurae. Spissa genus fluens electromagnetici plus pretiosius est quam genus fluens electromagnetici integratum. Princeps causa est, quod propter scissuram pecuniae pretiosae genus est munitum filum pecuniae.
  3. Flosmeter dividitur in: genus ordinarium, genus anti-corrosionis, genus anti-corrosionis. Pretium fluxus electromagnetici altior est quam fluxus electromagnetici ordinarii. Ratio pluris est, quia tunica distinguitur. Genus anti-corrosionis est enascentia tetrafluoroethylenae, maxime ad medium acidum Alkaline metiendum. Commune genus est Flexilis oblinit, maxime ad metiendam purgamentorum et mediae aquae ordinariae.

  1. Secundum vexillum output signum nexus et excitatio (vel copiae potentiae) nexus, sunt systema filum quattuor et ratio filum duo;
  2. Secundum modum conventus convertentis et sensoris, sunt scindendi genus et genus integrale;
  3. Secundum connexionem methodi sensoris et pipelineorum fluxus, exstant flange genus, genus clamiationis, genus sanitatis, et genus inserendi;
  4. Iuxta an electronica sensoris fluxi cum liquido mensurato contactum sit, genus contactuum sunt et typus non-contactus;
  5. Secundum structuram sensoris fluxus, breves tubuli genus sunt et obturaculum-in typo (plug-in fluens electromagneticus);
  6. Ex proposito classificatae sunt genus generale, genus explosio-probationis, genus sanitatis, genus anti-intrusionis et genus tributorum (fluxus apertus canalis) pro canali aperto mensurae fluunt.

Ut tibi placet: Digital Flow Meters Guide| Liquid et Gas

Flowmetri magni sunt in plantis curationum aquarum metiendis tractata et increatos purgamentorumprocessus aquae, aquae, et oeconomiae.

Unde uti potes fluxus magnetico metri

Aquae et aquae wastes includunt custodiam liquorum et translationem in fistula maxima inter areas aquarum/vastitates.

Applicationes in fodienda et minerali processus industries includunt processus aquae et processus slurry rivi et gravia media flumina.

In usu usus, industria aquae vastae, chemica, cibi et potus, oleum et gas (quamvis non pro humoribus olei et gasi, sed in processuum auxilio), potentia, pulpa et charta, metalla et metalla, et pharmaceutica.

Cum fluens electromagneticus aptum eligens, Sino-Inst suadet ut sequentes parametri vicissim consideres:

  1. Fistula diam;
  2. Institutionis structura;
  3. Electrode materia;
  4. Materia enascentia;
  5. Virtus suppeditat postulata;
  6. Signum output requisita;
  7. Pipeline pressus;
  8. temperatus medium

Lectio extensa: Quid est differentia inter Rotameter Et Flow Meter?

installation iudicium

Magneticum metrum fluere institutionem guidelines
  1. Medium mensuratum debet esse liquidum conductivum. Tibia implenda. Nulla porttitor neque sit amet orci.
  2. Per institutionem, fluens directio medii mensurati stat cum directione fluere metri indicatam;
  3. Recta fistula 5DN sectio in fronte et 3DN in tergo praestanda est (DN est diameter.). Si ametes sunt ut valvulae, cubiti, et capita in sectione anteriori minuentes, suadetur ut ante 10DN et post 5DN.
  4. Flosmeter vitandus est quam maxime: pressio negativa in tubo mensurae. Vitare magnas vibrationes. Gas mordax et alia loca aspera circum ambitu institutionis;
  5. Flometer ferromagnetica obiecta et apparatum cum validis campis electromagneticis vitare debet (ut magnis motoribus, magnis transformatoribus, etc.). Ne attingat campum magneticum et signum sensoris currentis;
  6. Pro opportunitate conservationis, suadetur ut fistulam bypassim ad institutionem fluens locum instituat.
  7. Cum Flometer in alta altitudine vel subterraneo instituitur, spatium ad institutionem, debugging et sustentationem asservari debet. Praeterea mensuras secundum diversas gradus tutelae correspondentes efficiunt;
  8. Corrosivitatem medii mensurati et proprietates fluminis plene intelligant, et stricte impediant ne corrodantur;
  9. Cum glutino vel flamma prope sensorem secans, caveas solitudo, ne tunica calefaciat. Et confirmari debet quod instrumentum sensoris lineae signo connectitur ne sensori laedatur.
Magneticum metrum fluere institutionem guidelines 1
Magneticum metrum fluere institutionem guidelines 2

Lectio extensa: Flowmeter Types insertio

  1. Massa metris fluunt et electro fluunt metra diversa genera metrorum fluunt. Massa fluere metri molem metitur humoris. Flos electromagneticus est volumen Flosmetricum, quod volumen fluidi mensurat.
  2. Massa metri fluens metiri potest instrumentis non conductivis. Media autem specialiora sunt ut caliditas, humilis caliditas et viscositas alta. Flometers electromagneticorum non solum metimur media conductiva, plerumque wastewater.
  3. Accurate metrum fluere massae altiorem est.
  4. Sumptus massae fluunt metrorum pluries quam metra fluunt electromagneticorum.

Lectio extensa: tubus metallum fluxus meter

Ut tibi placet:

Aqua calida fluunt Meters

Aquae calidae Fluxus Meters Amplio Heating-Boiler Systema Aquae calidae metra fluxus referuntur ad metra fluunt quae metiuntur et indicant fluxum aquae caliditae caliditatis. Aqua calida late usus est in industria et in usu civili. Ut systemata calefaciendi,…

Aquae Ultrasonic Metrum pro Residentialibus Aquae

Aqua metri ultrasonica novum parvum metrum residentiale est. Metra aquarum residentialium ultrasonica instructa sunt cum metris lineis aquae, et metra aquae wireless nativus esse potest. Sino-Inst varias metrorum fluxus ultrasonicae pro fluunt mensurae praebet. Si…

Dual Channel Ultrasonic Meter

Sino-Inst varias metrorum fluxus ultrasonicae pro fluunt mensurae praebet. Si quaestiones habes, colloquere fabrum venditiones nostras. Lege plura de: Quomodo opus metri residentiale aqua? aqua metri institutionem details Installation and use of ultrasonic water…

Aquae Fluxus Meter Ultrasonic insertio

Aquae Ultrasonicae Meter Fluxus est novum genus aquae metri magnae resource destinatum ad aquam. Utens ultrasonic temporis differentia mensurae technologiae. Features Insertionis Ultrasonic Aquae Fluxus Meter Quantum est 2 inch aqua metri fluens? Inueniamus…

Fluxus Meters Aquae Digitalis

Quid est metrum aqua digitalis fluere? A Digital aqua fluens metrum est metrum fluens quod aquam rate fluere potest ostendere et pro rate fluere output habere. Sicut 4-20mA output, HART, RS 485, et sic in…

Steel flow Meters

Immaculata chalybea fluunt metra, fiunt ferro immaculata, pro fluxu sensoris. Cum flos metiri debet in mundi ambitu, chalybs incorrupta fluens eligetur. Vel, cum mensurae ambitus vel mensurae medium est...

Biogas Flow Meters Electio Guide

Biogas Fluxus Metra sunt instrumenta quae fluxum biogas metiri possunt. Posset esse vortex profluxus metri, massae metri scelerisque, etc. Vulgo in biogas stationibus, biogas obterere productionem fermenti, etc. Sino-Inst varias praebet Biogas Flow…

Cibus Industrial Fuel Meters

Quid est cibus metri fluxus? Cibus fluxus metri est instrumentum quod cibus monitoris fluere potest. Fuel industrialis est fons energiae magni momenti. Exempli gratia, Diesel, cibus marinus, gasoline, etc. Sino-Inst varias offert cibus fluxus metrorum…

Sino-Inst offer super 50 Magnetic Fluxus Metra cum optimo Pretio.

A varietate O Magna Meters optiones tibi praesto sunt, sicut exemplaria gratuita, exemplaria soluta.

De XIII% horum sunt magneticus fluxus meter, In VII% Insertio Magna Flow Meter, In VII% Venturi fluunt metri; XXV% are ultrasonic fluxus metri; Sunt et alii, Liquid Turbine Flow Meters.

Sino-Inst est Fluxus Magneticus Metra praebitorum, qui in Sinis sita est. Fluxus Magneticus Metra producta maxime popularis sunt in America Septentrionali, Medio Oriente, et Europa Orientali. Civitates Americae Unitae, et Indiae, quae 99%, 1%, et 1% metrorum magneticarum fluunt.