Turbine Insertion Flow Meter

Insertion Flow Meter is widely used for flow measurement of large diameter pipes. Insertion Turbine Flow Meter is also called insertion type turbine flow meter.

Turbine Insertion Flow Meter

Insertion Turbine Flow Meter is designed for accurate, cost-effective flow measurement of large pipes. Insertion Turbine Flow Meter utilizes an electronic turbine rotation sensing system and unique low-quality turbine design. It provides process flow measurement for steam, gas, and high-temperature liquid Reliable solution. Of course, according to different application environments, different versions of plug-in flow meters can be provided, such as fixed, adjustable, bidirectional, and high pressure.

Insertion Turbine Flow Meter reference price: USD 350-900/pc.

Sino-Inst offers a variety of  Turbine flow meters for flow measurement. If you have any questions, please contact our sales engineers.

Features of Turbine Insertion Flow Meter

SI- LWCB/Q SERIES Insertion Turbine Flowmeters for Liquids and Gas 4”-72” Pipe Diameters

LWCQ featuresLWCB features
Strong anti-impurity ability. The tangential impeller can release suspended debris in the fluid at any time when it is rotating so that it will not be wound on the blades of the tangential impeller;The structure and principle of the sensor and display instrument are very simple and intuitive. It is especially easy for users to master its use and maintenance technology;
Strong anti-electromagnetic interference and anti-vibration ability;Strong anti-electromagnetic interference and anti-vibration ability;
The structure and principle of the sensor and display instrument are very simple and intuitive. It is especially easy for users to master its use and maintenance technology;The sensor can be installed in the open air. The entire sensor can be submerged in water for a long time;
After replacing the impeller and bearing, the meter coefficient remains unchanged;The flow range is wide and the lower limit flow rate is low.
Wide flow range. Low lower limit flow rate;The metering error of the complete set of flowmeters to the total fluid is small.
The measurement error of the complete set of the flowmeter to the total fluid is small;Almost no pressure loss. Save power and power consumption.
Almost no pressure loss. Save power and power consumption;After replacing the impeller and bearing, the meter coefficient remains unchanged;
The sensor can be installed in the open air. The entire sensor can be submerged in water for a long time;Sensors with shut-off valves. There is no need to cut off the flow during installation and removal;
Sensors with shut-off valves. There is no need to cut off the flow during installation and removal;Horizontal, vertical, and inclined pipes can be used;
Horizontal, vertical, and inclined pipes can be used;The purchase, installation, and maintenance costs of complete flowmeters are low.
The purchase of complete sets of flowmeters. Low installation and maintenance costs;

Specifications Of Turbine Insertion Flow Meter

Accuracy±5% 、±2.5%
Insertion depthWhen the inner diameter (DN) of the tested pipe is ≤1050mm, the insertion depth is:
LWCQ: 0.5×DN-20mm
LWCB: 0.5×DN
Nominal pressure1.0 MPa
Measured liquid temperature-20℃~120℃
Ambient temperature-20 ℃~70 ℃
Distance from the sensor to display meterUp to 1000m or more
Requirements on the length of straight pipeThe length of the upstream straight pipe section of the sensor should not be less than 20DN, and the length of the downstream straight pipe section should not be less than 7DN to ensure measurement accuracy.
If the length of the straight pipe section cannot meet this requirement, the on-site calibration instrument coefficient K can be used after on-site calibration is carried out under the condition of on-site calibration.

Flow Range

Model Measured inner diameter of pipe  mm Insert rod length mm The flow range corresponding to the nominal diameter DN m3/h
Full flow range Accuracy is ±2.5% of the flow range of the displayed value Accuracy is the flow range of ±5% of the displayed value
LWCQ-100* 100   6-150 10-150 <10-6
LWCQ-150 150 13-200 20-200 <20-13
LWCQ-200 200 23-300 40-300 <40-23
LWCQ≤400* 100 906 6-150 10-150 <10-6
150 13-200 20-200 <20-13
200 23-300 40-300 <40-23
250 36-450 62-450 <62-36
300 52-650 90-650 <90-52
350 70-900 120-900 <120-70
400 92-1100 160-1100 <160-92
LWCQ≤800 500 1106 150-1800 250-1800 <250-150
600 220-2500 360-2500 <360-220
700 280-3500 450-3500 <450-280
800 380-4500 640-4500 <640-380
LWCQ>800* 900 1306 460-5800 800-5800 <800-460
1000 600-7000 990-7000 <990-600
1100 700-8500 1200-8500 <1200-700
Model Measured inner diameter of pipe  mm Insert rod length mm The flow range corresponding to the nominal diameter DN m3/h
Full flow range Accuracy is ±2.5% of the flow range of the displayed value Accuracy is the flow range of ±5% of the displayed value
LWCB-100* 100   3-150 5-150 <5-3
LWCB-150 150 7-200 10-200 <10-7
LWCB-200 200 12-300 20-300 <20-12
LWCB≤400* 100 900 3-150 5-150 <5-3
150 7-200 10-200 <10-7
200 12-300 20-300 <20-12
250 18-450 31-450 <31-18
300 26-650 45-650 <45-26
350 35-900 60-900 <60-35
400 46-1100 80-1100 <80-46
LWCB≤800 500 1100 75-1800 125-1800 <125-75
600 110-2500 180-2500 <180-110
700 140-3500 225-3500 <225-140
800 190-4500 320-4500 <320-190
LWCB>800* 900 1300 230-5800 400-5800 <400-230
1000 300-7000 495-7000 <495-300
1100 350-8500 600-8500 <600-350
Model Description
LWC—
Impeller Q     Tangential
B Axial
Structure  ≤or> Indicates a shut-off valve
Indicates no shut-off valve
Diameter (mm) User pipe diameter

Model example
Example 1: LWCQ-100, which means no stop valve, nominal diameter DN100mm
Example 2: ≤400, it means there is a stop valve, the nominal diameter DN≤400mm
Example 3: LWCQ>800, it means there is a stop valve, the nominal diameter DN>800mm

Read More about: What is the difference between rotameter and flowmeter?

Turbine Insertion Flow Meter Working Principle

The plug-in turbine flowmeter is a new domestic velocity flowmeter. The turbine head, detection coil, etc. are designed as a combined plug-in. Because of its small size, the installation hole is also small. Therefore, a ball valve can be used to solve the problem of closing the installation hole.

More ingeniously, the insertion rod is made into a trapezoidal screw. When you need to remove it, you don’t need to stop the water. You can first rotate the trapezoidal screw to gradually raise the turbine head. After passing the upper ball valve, rotate the handle of the ball valve to close the pipeline. You can continue to spin up the turbine until it is removed. After installation and reset, proceed in reverse order. The same can be achieved without stopping the water.

The impeller inserted into the detection head of the plug-in turbine flowmeter is rotated by the fluid. The magnetic resistance of the magnetic circuit of the detection coil is periodically changed. The magnetic flux in the detection coil is periodically changed. Therefore, electric pulses are induced in the detection coil. Flow signal. The frequency f (times/second) of this signal is proportional to the volumetric flow Q (m3l second) flowing through the pipeline. The proportional coefficient is the meter coefficient K of the sensor, so f=K”Q.

The electrical pulse signal is amplified by the preamplifier and sent to the secondary instrument. Its waveform is rectangular pulse. After further enlargement and shaping, it is divided into two ways.

Send coefficient conversion circuit all the way. Then the power amplifier is sent to the totalizer. Obtain the cumulative volume flow. The other way sends the frequency dividing circuit. Then output 0~10mA (or 4~20mA) current signal through frequency/current conversion. At the same time, the instantaneous flow rate is displayed on the secondary meter.

Extended Reading: What is difference between rotameter and flow meter

Each SI- LWCB/Q Flow Meter is provided with a 4-20mA analog output for flow rate,

pulse output for totalization and a built-in user interface and display.

The standard loop-powered meter also includes HART.

Know more about: Turbine type Flow Meter

Applications of Turbine Insertion Flow Meter

Precision flow measurement of liquid and gas applications in large diameter pipes at a lower cost than using an in-line flow meter.

SI- LWCB/Q Series Insertion Flow Meters are designed to work in pipe sizes, ranging from ¾” to 72″ in diameter (1″ for copper).

Insertion Turbine Flow Meter application

Uses for the turbine flow meters include:

  • Chilled Water
  • Hot Water
  • Condenser Water
  • Domestic Water
  • Process Cooling
  • Steam Condensate and Brine.

Extended reading: 2 inch Water Flow Meter

Guess you like: Insertion Magnetic Flow Meter-Large diameter online install

Steam Insertion flow meter

SI- LWCB/Q Series Insertion Turbine Flow Meters, can measure the steam.

And, Sino-Inst also offers:

Steam Vortex Flow Meters are designed for accurate, cost-effective mass flow measurement of saturated steam.

The standard loop-powered version of the vortex flowmeter is equipped with the internal temperature compensation required for direct mass flow measurement. Steam Vortex Flow Meter is provided with a 4-20mA analog output for flow rate, pulse output for totalization, and a built-in user interface and display. The standard loop-powered meter also includes HART.

Read more about: Steam pressure transmitter-Pressure measure on steam pipeline 

Natural gas flow meters

The gas turbine flowmeter integrates temperature, pressure, flow sensors and intelligent flow totalizers. The gas turbine flowmeter has high accuracy and good repeatability, so it is suitable for trade measurement and industrial process detection. It is widely used in many kinds of gas in petroleum, chemical, metallurgy, aviation, scientific research and other sectors and industrial fields. Such as natural gas, city gas, propane, butane, air, nitrogen and other gases measurement.

More Featured Insertion Flow Meter

Frequently
Asked
Questions

Turbine flow meters are velocity flow meters, also called impeller flow meters. Can be used to measure the instantaneous flow and cumulative flow of liquids and gases.

Turbine flowmeters are widely used in flow measurement: petroleum, organic liquids, inorganic liquids, liquefied gas, natural gas, coal gas and cryogenic fluids. Turbine flowmeter signals can be divided into pulse signals or current signals (4-20mA). It is suitable for use with secondary display, PLC, DCS and other computer control systems.

Extended reading: Turbine Flow Meter Advantages and Disadvantages

Simply put. The turbine flow meter has a turbine. It needs to be installed in the fluid pipeline when in use, and both ends are supported by bearings.

When the fluid passes through the turbine. The fluid hits the turbine blades. Drive the rotation of the turbine blades. The flow rate is measured indirectly through the angular velocity of the turbine blades. The method used is that the angular velocity of the blades is proportional to the fluid velocity.

Extended reading: Liquid Turbine Flow Meter Working Principle

At present, there are many kinds of Insertion flowmeters in use. According to the working principle of the Insertion flowmeter detection head, it can be divided into Insertion turbine, Insertion vortex, Insertion electromagnetic, Insertion ultrasonic, and Insertion target flowmeter.

More Featured Insertion flowmeters

Insertion flow meter is a type of flow meter divided by structure, which includes various flow meters with different working principles.

Insertion flow meter has a great development. Insertion flow meter has been promoted and used in many forms.

According to the working principle of the Insertion flow meter detection head, it can be divided into plug-in turbine, plug-in vortex, plug-in electromagnetic, uniform velocity tube and thermal flow meter.

According to the number of measurement points of the Insertion flow meter, it can be divided into two categories: point flow type and runoff type.

Extended reading: Metal Tube Flow Meter-Variable Area Flow Meters Principle

Water flow meters are flow meters that can diaplay the flow rate of industrial water pipe.

A water flow meter measures the amount of water flowing through a pipe. We have several kinds to choose from, depending on the application, maintenance needs, and budget.

Read more about Water flow meter types.

Extended reading: Featured Cheap flow meters for Sale

Sino-Inst’s insertion turbine flow meters provide significant cost, savings for line sizes from 2 to 80′ without compromising performance.

With high accuracy, wide turndown, and a unique low-mass rotor design without welded joints, the insertion turbine flow meter gives you the benefit, of more than 10 years of practical experience.

Request a Quote

Please enable JavaScript in your browser to submit the form
This entry was posted in Turbine Flow Meters, Flow Meters, Liquid Flow Meters and tagged by KimGuo11. Bookmark the permalink.

About KimGuo11

Wu Peng, born in 1980, is a highly respected and accomplished male engineer with extensive experience in the field of automation. With over 20 years of industry experience, Wu has made significant contributions to both academia and engineering projects. Throughout his career, Wu Peng has participated in numerous national and international engineering projects. Some of his most notable projects include the development of an intelligent control system for oil refineries, the design of a cutting-edge distributed control system for petrochemical plants, and the optimization of control algorithms for natural gas pipelines.