Flange Mounted Differential Pressure Transmitter

The Flange Mounted Differential Pressure Transmitter is based on an intelligent differential pressure transmitter and features a flush-mounted or extended flange. It is suitable for measuring the level, differential pressure, and density of liquids that are prone to crystallization or sedimentation. Equivalent to model EJA210E.

Can be directly installed on tanks or pipelines. It is used for measuring high-temperature, easily solidifying or crystallizing, suspended solids-containing, highly viscous, highly corrosive, or other media that require hygienic conditions and cannot be contaminated.

Sino-Inst offers a variety of flange-mounted DP transmitters for industrial pressure measurement. If you have any questions, please contact our sales engineers.

Sino-Inst Flange Mounted Differential Pressure Transmitter uses advanced microprocessing technology and digital communication technology. It outputs a 4~20 mA DC signal corresponding to the measured differential pressure. It can also be configured with the HART protocol.

Flange Mounted Differential Pressure Transmitter Features:

  • Used to measure the differential pressure of corrosive and non-corrosive gases, steam and liquids;
  • Using a stainless steel diaphragm;
  • Applicable to various hazardous places;
  • Output linear DC current proportional to the differential pressure value;
  • Provide various isolation diaphragms to meet special applications, such as liquid level measurement, corrosive media;
  • High measurement accuracy, 0.1%FS, 0.5%FS;
  • Extensible measurement range;
  • Aluminum and stainless steel housing;
  • With intrinsically safe explosion-proof and isolated explosion-proof capabilities. Can be used in various hazardous places.

Extended reading: Smart Differential Pressure Transmitter

Specification of Flange Mounted Differential Pressure Transmitter

ModelTransmitter type
SMT3151LTFlange Mounted Differential Pressure Transmitter
CodeScale range
40-4.0~40kPa(0-400~4000mmH2O)
50-20~200kPa(0-2~20mH2O)
60-70~700kPa(0-7~70mH2O)
70-210~2100kPa(0-21~mH2O)
CodeOutput form
ELinear output 4-20mAdc
SFLinear output 4-20mAdc +HART signal
FMODBUS-485 signal
CodeFlange standard (high pressure side flange)
AANSI American Standard (HG20615)
DDIN European Standard (HG20592)
CodeProcess connection size
ANSI American Standard (HG20615)DIN European Standard (HG20592)
251”DN25
401.5”DN40
502”DN50
803”DN80
04”DN100
CodeProcess connection pressure rating
ANSI American Standard (HG20615)DIN European Standard (HG20592)
A150LBPN16/25
B300LBPN40
C600LBPN64
D900LBPN100
CodeHigh pressure side diaphragm
A316 stainless steel
BHastelloy C
CMonel
DTantalum
ETitanium
FSpecial Requirements
CodeHigh pressure side insert tube lengthHigh pressure side insert cylinder material
A0 mmNone
B50 mm316L Stainless steel
C150 mm316L Stainless steel
D200 mm316L Stainless steel
CodeHigh pressure side filling fluid
DGeneral silicone oil  (-40~104℃)
FHigh temperature silicone oil   (-40~304℃)
SInert liquid  (-40~204℃)
Low pressure side structural materialFlange (joint)Exhaust/drain valveIsolation diaphragmSensor filling fluid
22316 Stainless steel316 Stainless steel316 Stainless steelSilicone oil
23316 Stainless steel316 Stainless steelHastelloy CSilicone oil
24316 Stainless steel316 Stainless steelMonelSilicone oil
25316 Stainless steel316 Stainless steelTantalumSilicone oil
33Hastelloy CHastelloy CHastelloy C Silicone oil
35Hastelloy CHastelloy CTantalum Silicone oil
44MonelMonelMonel Silicone oil
S2A remote transmission device (with a remote transmission device on the low-voltage side)
CodeShell materialConduit inlet dimensions
ALow copper aluminum alloy polyurethane coatingM20×1.5
BLow copper aluminum alloy polyurethane coating1/2-14 NPT
CStainless steelM20×1.5
DStainless steel1/2-14 NPT
CodeOptional parts
M10~100%  Linear indicator head
M4LCD multi – power digital display head
D1Side discharge valve at the top (only for the low pressure side of the low pressure side without remote transmission)
D2Side discharge valve at the top (only for the low pressure side of the low pressure side without remote transmission)
DaFlameproof  ExdIIBT5Gb;(explosion-proof certificate no. : CE16.1163)
FaIntrinsically safe ExiaIICT4 / T5 / T6Ga;(explosion-proof certificate no. : CE15.2354X)
CXWith corresponding 316 flushing ring

Extended Reading:

Applications

The Flange Mounted Differential Pressure Transmitter can accurately measure the liquid level and density of various containers. There are two types of flat flange and insert flange. It is suitable for high-viscosity medium or suspended liquid measurement.

  1. Viscous medium at high temperature;
  2. Easily crystallized medium;
  3. Precipitation medium with solid particles or suspended matter;
  4. Strongly corrosive or highly toxic medium;
  5. It can eliminate the leakage of the pressure guiding pipe and pollute the surrounding environment. It can avoid the instability of the measurement signal when the isolation liquid is used. The tedious work of frequently supplementing the isolation liquid is required;
  6. Continuously and accurately measure the interface and density;
  7. The remote transmission device can avoid the mixing of different instantaneous media so that the measurement results truly reflect the actual situation of process changes;
  8. Places with high sanitation requirements;
  9. Such as in the production of food, beverage, and pharmaceutical industries. Not only the transmitter contacting the media parts meet hygienic standards, but also should be easy to wash. To prevent cross-contamination of different batches of media.

Pressure level transmitter is good for level measurement. Most of the time, we use submersible hydrostatic level sensor for the level measurement. When you can not use the probe of hydrostatic level sensor, you can try with this pressure level transmitter. Pressure level transmitter, is one type of DP level measure instrument, with the diaphragm.

More

The SMT3151LT differential pressure level transmitter is a new type of differential pressure transmitter manufactured using advanced technology and equipment. Equipped with dual remote seals, it can be used for continuous measurement of liquid level, flow rate, and differential pressure. It offers particular advantages in applications involving sealed storage tanks.

More

Flange Mounted Differential Pressure Transmitter Working principle

Differential Pressure Transmitter structure
1. Headcover; 2. Head; 3. Metal bulkhead; 4. Shell; 5. Nameplate label; 6. Explosion-proof joint; 7. Terminal block; 8. Head cover; 9. Drain valve; 10. Bolt; 11. Clamp; 12. Sensor seal; 13. Sensor; 14. Nut; 15. Welded pipe joint assembly
Differential pressure DPlevel transmitter
diaphragm seal

Differential pressure transmitters utilize the pressure difference generated by the liquid’s own gravity to measure the liquid level in a container.

Flange-mounted differential pressure transmitters are directly installed on pre-existing flanges at the bottom of pipes or containers, contacting the liquid through an isolation diaphragm.

When the diaphragm is subjected to pressure, it undergoes slight deformation. The displacement of the diaphragm changes with the differential pressure. This change is precisely converted by an amplification circuit into a 4-20mA DC two-wire current, voltage, or digital HART output signal, thus achieving pressure measurement and transmission.

The high-pressure side measuring tube is always filled with the medium, maintaining constant pressure. The low-pressure side measuring tube forms a communicating vessel with the container, and its pressure changes linearly with the liquid level in the container.

Let △P be the differential pressure signal received by the transmitter, P0 be the internal pressure of the container, P+ be the pressure on the positive pressure side of the transmitter, and P- be the pressure on the negative pressure side of the transmitter. Let ρ be the density of the liquid in the container, g be the acceleration due to gravity, h1 be the height from the process zero point to the upper pressure tap of the container, h2 be the process liquid level in the container, and h be the height from the transmitter to the process liquid level zero point.

Then:
P+ = P0 + ρgh1 + ρgh
P- = P0 + ρgh2 + ρgh
△P = P+ – P- = ρgh1 – ρgh2

When the liquid level changes from h2=0 to h2=h1, the differential pressure measured by the transmitter changes from its maximum value to △P=0. By configuring the transmitter, the output current changes from 4mA to 20mA.

You may like: differential pressure transmitter working principle|Working Principle of pressure level transmittersdifferential pressure level transmitter working principle

Single flange vs Double flanges differential pressure level transmitter

Differential Pressure Level Transmitters
  1. In principle: all are differential pressure transmitters + flange guide pressure;
  2. In terms of structure: the single flange liquid zd position transmitter has only one flange diaphragm box connected to the high pressure side, and the low pressure side to the atmosphere. The double flange liquid level transmitter is high and low pressure side through oil-filled capillary It is connected with two flanged membrane return boxes. There is also a capillary. The single flange transmitter is installed below, and a capillary is drawn from the low pressure side of the single flange transmitter to the upper flange membrane box.
  3. In terms of engineering applications: all can only measure the liquid level of fixed density. The single-flange transmitter can only be used for the liquid level of atmospheric equipment that can be imagined with the atmosphere. The double-flange transmitter can be suitable. Answer: Use closed equipment kettle to measure liquid level;
  4. From the economical point of view, the double flange is definitely more expensive than the single flange. After all, there is one more flange capsule and capillary.
SI 801 Piezoresistive Differential Pressure Transmitter
Piezoresistive Differential Pressure Transmitter
Piezoresistive Differential Pressure Transmitter utilizes the piezoresistive effect of semiconductor silicon materials. Realize accurate measurement of differential pressure.
Smart Differential Pressure Transmitter
Smart Differential Pressure Transmitter
Smart Differential Pressure Transmitter measures industrial differential pressure. Can Works with diaphragm seals, capillary, HART. Outputs standard signals (such as 4 ~ 20mA, 0 ~ 5V).
Diaphragm seals also known as chemical seals or remote seals
Diaphragm Seal Pressure Transmitter
When the process medium should not come into contact with the pressured parts of the measuring instrument. Diaphragm sealed pressure transmitters are used for pressure measurement.
High Temperature Pressure Transmitter
High-Temperature Pressure Transmitter
High-temperature pressure transmitters with a 4-20mA output.
which has a temperature capability of over 850 °C and is not pyroelectric.

More Pressure and Level Measurement Solutions

Sino-Inst is one of the most excellent DP transmitters, pressure transmitters, and level transmitters suppliers. Sino-Inst can offer you a complete solution for pressure transmitters.

Sino-Inst can offer you with Flange Mounted Differential Pressure Transmitters. Our transmitters can work for you just like EJA210E.

Our Flange Mounted Differential Pressure Transmitters are widely exported to various countries. Including USA, UK, Argentina, Singapore, etc. If you need to purchase Flange Mounted Differential Pressure Transmitter, or have related technical questions, please feel free to contact our sales engineers!

Request a Quote